Drive Fix Helical Remedial Wall Tie SDS Install Tool Replacement Embedment Tip
Drive Fix Helical Remedial Wall Tie SDS install tool replacement embedment tips for use with the Drive Fix Helical Remedial Wall Tie SDS Install Tool
Typical install volume for an embedment tip before it needs replacing is approximately 300 wall ties.
Drive Fix Helical Remedial Wall Tie SDS Install Tool are available in 8mm and 10mm sizes according to the diameter of wall tie you are installing. Replacement embedment tips are also supplied in 8mm and 10mm sizes. Please seclect the correct size.
Installation procedure as per manufacturers data sheet:
Insert the SDS adaptor into the SDS hammer drill, then set to hammer only. Then place the wall tie into the adaptor and offer to the pre-drilled substrate.
Drive the wall tie fully home until the shoulder of the adaptor hits the substrate.
Insert the appropriate size embedment tip into the SDS adaptor.
Locate the end of the tie into the embedment tip, then drive the tie fully home until the tie is below the surface of the substrate.